Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 546
Filter
2.
Journal of Central South University(Medical Sciences) ; (12): 221-230, 2023.
Article in English | WPRIM | ID: wpr-971389

ABSTRACT

OBJECTIVES@#Surgical robot system has broken the limitation of traditional surgery and shown excellent performance in surgery, and has been widely used in minimally invasive treatment in most areas of surgery. This study aims to verify the basic performance of the domestic surgical robot system and the safety and effectiveness of the integrated bipolar electrocoagulation and ultrasonic knife.@*METHODS@#The basic performance of the domestic surgical robot system was evaluated by completing the square knot and surgical knot, vertical and horizontal perforation and right ring perforation and suture, as well as picking up beans. Compared with laparoscopy, the safety and effectiveness of the domestic surgical robot after integrated interconnection bipolar electrocoagulation and ultrasonic scalpel were evaluated by detecting the vascular closure performance and the degree of histopathological damage in animals.@*RESULTS@#Compared with freehand knotting, domestic robot knotting speed and circumference were slightly worse, but better than laparoscopic knotting. There was no statistical significance in the tension difference of the surgical knots among the 3 methods (P>0.05), but the tension of the square knots made by the freehand and the domestic surgical robot was greater than that of the laparoscopy (P<0.05). The space required for both the left and right forceps heads of knots was smaller than that of laparoscopy (P<0.001), which successfully completed the 4 quadrant suture tasks, and the time of picking up beans was significantly less than that of laparoscopy (P<0.05). There was no significant difference in the temperature of the liver tissue after the bipolar electrocoagulation between the interconnected domestic surgical robot and the laparoscopy (P>0.05), and the acute thermal injury was observed under the light microscope. The temperature of the liver tissue treated by the domestic robotic ultrasound knife was higher than that of the laparoscopic ultrasound knife (P<0.05).@*CONCLUSIONS@#Domestic surgical robots are obviously superior to laparoscopy in suturing, knotting, and moving objects, and domestic surgical robots' interconnect bipolar electrocoagulation and ultrasonic knife have achieved success in animal experiments, and hemostasis is considered to be safe and effective.


Subject(s)
Animals , Robotics , Laparoscopy/methods , Ultrasonography
3.
Chinese Journal of Surgery ; (12): 498-502, 2023.
Article in Chinese | WPRIM | ID: wpr-981031

ABSTRACT

Objective: To analyze the short-term clinical effects of robot-assisted and laparoscopic repair of the hiatal hernia. Methods: The clinical data of 56 patients underwent minimally invasive hiatal hernia repair from January 2021 to January 2022 in the Department of Minimally Invasive Surgery, Hernias and Abdominal Wall Surgery, People's Hospital of Xinjiang Uygur Autonomous Region were retrospectively analyzed. There were 32 males and 24 females, aging (59.7±10.7) years (range: 28 to 75 years). All patients were divided into laparoscopy group (n=27) and robot group (n=29) according to surgical procedures. Perioperative conditions, hospital stay, and improvement in symptoms before and after surgery were compared between the two groups by the t test, Wilcoxon rank-sum test and χ2 test. Results: All surgical procedures were successfully completed, without conversion to laparotomy or change in operation mode. There were no serious complications related to the operation. The intraoperative blood loss of the robot group was less than that of the laparoscopic group (M (IQR)): (20 (110) ml vs. 40 (80) ml, Z=-4.098, P<0.01). The operation time ((111.7±33.6) minutes vs. (120.4±35.0) minutes, t=-0.943, P=0.350) and hospitalization time ((3.9±1.4) days vs. (4.7±1.9) days, t=-1.980, P=0.053) of the robot group and the laparoscopic group were similar. Follow-up for 12 months after the operation showed no postoperative complications and recurrence. The score of the health-related quality of life questionnaire for gastroesophageal reflux disease in the robot group decreased from 10.8±2.8 before the operation to 6.5±0.6 after the operation, and that in the laparoscopic group decreased from 10.6±2.1 before the operation to 6.3±0.6 after the operation. There was no difference in the influence of different surgical methods on the change in score (t=0.030,P=0.976). Conclusion: Compared with laparoscopic repair of the hiatal hernia, robot-assisted hiatal hernia repair has the advantages of less bleeding, rapid postoperative recovery and good short-term effect.


Subject(s)
Male , Female , Humans , Hernia, Hiatal/complications , Retrospective Studies , Robotics , Herniorrhaphy/methods , Quality of Life , Laparoscopy/methods , Recurrence , Fundoplication/methods
4.
Chinese Acupuncture & Moxibustion ; (12): 463-468, 2023.
Article in Chinese | WPRIM | ID: wpr-980745

ABSTRACT

The difficulties such as how to accurately locate acupoints and safely insert needles are presented in acupuncture robot. The puncture robot with high technological similarity to acupuncture robot is getting mature, and a large number of human trials and animal experiments have been conducted for the development of puncture robot. Through comparing the similarities and differences between puncture robot and acupuncture robot in the aspects of through-skin puncture, needle insertion and needle removal, the valuable technology of puncture robot is analyzed for the development of acupuncture robot, and the crucial direction of technology migration is determined. ①Integrating the mechanical feedback and medical imaging technology and utilizing the multi-modal perception to achieve the safety of acupuncture operation. ②Emphasizing the integration of the existing designs of chest puncture robot to realize the acupuncture operation with inhalation and exhalation involved. ③Focusing on the development of relevant technology of automatic needle removal through conducting the actual scenario of treatment with acupuncture robot in patients under non-anaesthetic condition.


Subject(s)
Animals , Humans , Robotics , Feasibility Studies , Acupuncture Therapy , Punctures , Acupuncture , Needles
5.
Chinese Journal of Gastrointestinal Surgery ; (12): 475-484, 2023.
Article in Chinese | WPRIM | ID: wpr-986816

ABSTRACT

Objective: To methodically assess the clinical effectiveness and safety of robot-assisted total rectal mesenteric resection (RTME), laparoscopic-assisted total rectal mesenteric resection (laTME), and transanal total rectal mesenteric resection (taTME). Methods: A computer search was conducted on PubMed, Embase, Cochrane Library, and Ovid databases to identify English-language reports published between January 2017 and January 2022 that compared the clinical efficacy of the three surgical procedures of RTME, laTME, and taTME. The quality of the studies was evaluated using the NOS and JADAD scales for retrospective cohort studies and randomized controlled trials, respectively. Direct meta-analysis and reticulated meta-analysis were performed using Review Manager software and R software, respectively. Results: Twenty-nine publications comprising 8,339 patients with rectal cancer were ultimately included. The direct meta-analysis indicated that the length of hospital stay was longer after RTME than after taTME, whereas according to the reticulated meta-analysis the length of hospital stay was shorter after taTME than after laTME (MD=-0.86, 95%CI: -1.70 to -0.096, P=0.036). Moreover, the incidence of anastomotic leak was lower after taTME than after RTME (OR=0.60, 95%CI: 0.39 to 0.91, P=0.018). The incidence of intestinal obstruction was also lower after taTME than after RTME (OR=0.55, 95%CI: 0.31 to 0.94, P=0.037). All of these differences were statistically significant (all P<0.05). There were no statistically significant differences between the three surgical procedures regarding the number of lymph nodes cleared, length of the inferior rectal margin, or rate of positive circumferential margins (all P>0.05). An inconsistency test using nodal analysis revealed no statistically significant differences between the results of direct and indirect comparisons of the six outcome indicators (all P>0.05). Furthermore, we detected no significant overall inconsistency between direct and indirect evidence. Conclusion: taTME has advantages over RTME and laTME, in terms of radical and surgical short-term outcomes in patients with rectal cancer.


Subject(s)
Humans , Robotics , Robotic Surgical Procedures/adverse effects , Network Meta-Analysis , Retrospective Studies , Postoperative Complications/etiology , Transanal Endoscopic Surgery/methods , Rectum/surgery , Rectal Neoplasms/pathology , Laparoscopy/methods , Treatment Outcome
6.
Chinese Journal of Medical Instrumentation ; (6): 32-37, 2023.
Article in Chinese | WPRIM | ID: wpr-971299

ABSTRACT

Characteristics of two major categories of RA equipment which defined in the standard are interpreted firstly. Few representative RA equipment in current market and their key product features are introduced. Then, classifications of different indexes of spatial positioning accuracy are declared, the difficulties of performing testing process on each indexes are further explained. Meanwhile, different kinds of three dimensional coordinate measuring equipment that are cutting edge at present stage are introduced with their main methods of use explained. According to characteristics of three dimensional coordinate measuring equipment on the market, proper measuring equipment for testing certain index of spatial positioning accuracy and corresponding experiment method are introduced.


Subject(s)
Robotics/standards , Robotic Surgical Procedures/instrumentation
7.
Chinese Journal of Medical Instrumentation ; (6): 26-31, 2023.
Article in Chinese | WPRIM | ID: wpr-971298

ABSTRACT

Due to the need to achieve precise operations during surgery, in order to prevent hand tremors and poor surgical field of view, more and more surgical robots are used in surgical operations combined with navigation technology to meet the requirements for surgical accuracy. Open surgery such as orthopaedics, joint replacement and neurosurgery on the market generally use optical navigation systems to guide robots to achieve precise positioning, but optical navigation systems cannot be used for operations in areas with small surgical space. Therefore, a robotic surgical system based on electromagnetic navigation technology that can be applied to the craniofacial area was proposed. By using this robot, the problems of difficult operation and low precision caused by the narrow craniofacial space can be solved. Key techniques and considerations are studied. The function of the developed prototype is verified through model tests. The test results show that the surgical robot under the electromagnetic navigation technology can achieve precise surgical operations improve the success rate of the doctor's surgery and reduce postoperative complications.


Subject(s)
Humans , Robotics , Robotic Surgical Procedures , Electromagnetic Phenomena , Postoperative Complications
8.
Chinese Journal of Medical Instrumentation ; (6): 1-12, 2023.
Article in Chinese | WPRIM | ID: wpr-971295

ABSTRACT

OBJECTIVE@#To study the development of surgical robots at home and abroad in recent years.@*METHODS@#Through a large number of literature review and analysis, the qualification approval and technical function characteristics of domestic and foreign surgical robots from January 2019 to July 2022 were analyzed.@*RESULTS@#The related situations of 39 surgical robots were analyzed and reported, and the shortcomings and future development direction of the current surgical robots were summarized.@*CONCLUSIONS@#The development of surgical robots in China is now in a rapid development stage. At present, surgical robots generally have the disadvantages of high cost, lack of tactile feedback (force feedback), large size, large space occupation and difficult to move. In the future, it will develop towards intelligent, miniaturized, remote, open and low-cost.


Subject(s)
China , Robotics , Robotic Surgical Procedures
9.
Chinese Journal of Traumatology ; (6): 83-93, 2023.
Article in English | WPRIM | ID: wpr-970967

ABSTRACT

PURPOSE@#Robot-assisted technology is a forefront of surgical innovation that improves the accuracy of total knee arthroplasty (TKA). But whether the accuracy of surgery can improve the clinical efficacy still needs further research. The purpose of this study is to perform three-dimensional (3D) analysis in the early postoperative period of patients who received robot-assisted total knee arthroplasty (RATKA), and to study the trend of changes in gait parameters after RATKA and the correlation with the early clinical efficacy.@*METHODS@#Patients who received RATKA in the Center of Joint Surgery, the First Hospital Affiliated to Army Military Medical University from October 2020 to January 2021 were included. The imaging parameters, i.e., hip-knee-ankle angle, lateral distal femoral angle, medial proximal tibial angle, posterior condylar angle were measured 3 months post-TKA. The 3D gait analysis and clinical efficacy by Western Ontario Mac Master University Index (WOMAC) score were performed pre-TKA, 3 and 6 months post-TKA. The differences in spatiotemporal parameters of gait, kinetic parameters, and kinematic parameters of the operated limb and the contralateral limb were compared. The correlation between gait parameters and WOMAC scores was analyzed. Paired sample t-test and Wilcoxon rank-sum test were used to analyze the difference between groups, and Spearman correlation coefficient was used to analyze the correlation.@*RESULTS@#There were 31 patients included in this study, and the imaging indexes showed that all of them returned to normal post-TKA. The WOMAC score at 3 months post-TKA was significantly lower than that pre-TKA, and there was no significant difference between at 3 and 6 months. The 3D gait analysis results showed that the double support time of the operated limb reduced at 3 and 6 months (all p < 0.05), the maximum extension and maximum external rotation of the knee joint increased at stance phase, and the maximum flexion angle, the range of motion and the maximum external rotation increased at swing phase. Compared with the preoperative data, there were significant improvements (all p < 0.05). Compared with the contralateral knee joint, the maximum external rotation of the knee joint at swing phase was smaller than that of the contralateral side, and the maximum flexion and extension moment was greater than that of the contralateral knee. The maximum external rotation moment of the joint was greater than that of the contralateral knee joint (p < 0.05). There was a negative correlation between the single support time pre-TKA and the WOMAC score at 3 months (p = 0.017), and the single support time at 3 months was negatively correlated with the WOMAC score at 6 months (p = 0.043). The cadence at 6 months was negatively correlated with the WOMAC score at 6 months (p = 0.031). The maximum knee extension at stance phase at 6 months was negatively correlated with the WOMAC score at 6 month (p = 0.048). The maximum external rotation at stance phase at 6 months was negatively correlated with the WOMAC score at 6 months (p = 0.024).@*CONCLUSION@#The 3D gait analysis of RATKA patients is more sensitive than WOMAC score in evaluating the clinical efficacy. Trend of changes in gait parameters shows that the knee joint support, flexion and extension function, range of motion, external rotation and varus deformity moment of the patient were significantly improved at 3 months after surgery, and continued to 6 months after surgery. Compared with the contralateral knee, the gait parameters of the operated limb still has significant gaps in functionality, such as the external rotation and flexion and extension. The single support time, cadence, knee extension, and knee external rotation of the operated limb have a greater correlation with the postoperative WOMAC score. Postoperative rehabilitation exercises should be emphasized, which is of great value for improving the early efficacy of RATKA.


Subject(s)
Humans , Arthroplasty, Replacement, Knee , Gait Analysis , Robotics , Osteoarthritis, Knee/surgery , Knee Joint/surgery , Treatment Outcome , Range of Motion, Articular , Biomechanical Phenomena
10.
China Journal of Orthopaedics and Traumatology ; (12): 221-225, 2023.
Article in Chinese | WPRIM | ID: wpr-970851

ABSTRACT

OBJECTIVE@#To investigate the clinical efficacy and advantages of Tianji orthopedic robot assisted cannulated screw internal fixation for femoral neck fracture.@*METHODS@#The clinical data of 41 patients with femoral neck fracture who underwent internal fixation with cannulated screws from January 2019 to January 2022 were retrospectively analyzed. According to different surgical methods, they were divided into Tianji robot group and traditional cannulated screw fixation group (traditional operation group). Among them, there were 18 patients in Tianji robot group including 8 males and 10 females with age of (56.00±4.22) years old, Garden typeⅠ (4 cases), type Ⅱ (11 cases), type Ⅲ (2 cases), and type Ⅳ (1 case). There were 23 patients in the traditional operation group, including 10 males and 13 females, aged (54.87±4.81) years old;there were 5 cases of Garden typeⅠ, 14 cases of type Ⅱ, 3 cases of type Ⅲ and 1 case of type Ⅳ. The operation time, intraoperative blood loss, fluoroscopy times, guide needle placement times, operation costs and other indicators were observed and compared between two groups. Harris score was used to evaluate hip joint function 12 months after operation.@*RESULTS@#The wounds of all patients healed in Grade A without complications. There were significant differences between two groups in terms of operation time, times of intraoperative fluoroscopy, times of guide needle placement, amount of intraoperative bleeding, and operation cost (P<0.05). All 41 patients were followed up for at least 12 months. The fractures of both groups were healed. There was no infection, screw loosening, fracture displacement and femoral head necrosis in Tianji robot group during follow-up;Screw loosening occurred in 2 patients in the traditional operation group during follow-up. At 12 months after operation, Harris hip joint function score of Tianji robot group was higher than that of traditional operation group in daily activity, lameness, joint activity score and total score (P<0.05).@*CONCLUSION@#Tianji robot assisted nail placement is a better method for the treatment of femoral neck fracture, which improves the surgical efficiency, is more accurate, has higher success rate of one-time nail placement, shorter operation time, less radiation, and has better hip joint function recovery after surgery.


Subject(s)
Male , Female , Humans , Middle Aged , Robotics , Retrospective Studies , Femoral Neck Fractures/surgery , Bone Screws , Fracture Fixation, Internal/methods , Treatment Outcome
11.
China Journal of Orthopaedics and Traumatology ; (12): 133-139, 2023.
Article in Chinese | WPRIM | ID: wpr-970834

ABSTRACT

OBJECTIVE@#To investigate the early efficacy of Mako robot-assisted total knee arthroplasty (TKA) in the treatment of knee osteoarthritis (KOA) and summarize the initial application experience.@*METHODS@#Retrospective analysis of 73 patients with KOA treated with Mako robot-assisted TKA from June 2021 to December 2021. There were 16 males and 57 females, aged from 54 to 81 years old with an average of (67.8±6.6) years old. The hip knee and ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), lateral femoral component angle (LFCA) and lateral tibial component angle (LTCA) were recorded and analyzed. WOMAC score and KSS were used to compare the functional recovery of patients preoperatively, 3 and 6 months postoperatively.@*RESULTS@#All the 73 patients were successfully treated without serious complications such as vascular and nerve injury, and all the incisions healed well at stageⅠwithout infection. The patients were followed up from 4 to 11 months with an average of (7.0±2.7) months, and the satisfaction rate of the last follow-up was 90.41% (66/73). WOMAC scores were (23.1±5.4) at 3 months and (14.8±4.1) at 6 months postoperatively. KSS clinical scores were ( 76.1±4.0) at 3 months and (82.1±3.7) at 6 months postoperatively;KSS functional scores were (74.3±3.1) at 3 months and (78.6±2.1) at 6 months after operation. Postoperative imaging showed good position of the prosthesis, HKA angle was (178.5±2.1)°, LDFA was (91.2±1.8)°, MPTA was(89.9±1.5) °, LFCA was (7.6±3.1)°, LTCA was (88.2±1.1)°. The mechanical axis within ±3° in sixty cases(82.2%), and the mechanical axis within ±6° in all the patients.@*CONCLUSION@#Mako robot-assisted TKA is a safe and effective surgery in the treatment of knee osteoarthritis, which exhibited good efficacy in the correction of lower limb alignment, soft tissue balance and improvement of knee function. The long-term efficacy needs further follow-up observation.


Subject(s)
Male , Female , Humans , Middle Aged , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/methods , Osteoarthritis, Knee/surgery , Retrospective Studies , Robotics , Knee Joint/surgery
12.
Journal of Biomedical Engineering ; (6): 141-148, 2023.
Article in Chinese | WPRIM | ID: wpr-970684

ABSTRACT

To explore the feasibility of applying magnetic stimulation technology to the movement control of animal robots, the influence of coil radius, number of turns and other factors on the intensity, depth and focus of magnetic stimulation was simulated and analyzed for robot pigeons. The coil design scheme was proposed. The coil was placed on the head and one of the legs of the pigeon, and the leg electromyography (EMG) was recorded when magnetic stimulation was performed. Results showed that the EMG was significantly strengthened during magnetic stimulation. With the reduction of the output frequency of the magnetic stimulation system, the output current was increased and the EMG was enhanced accordingly. Compared with the brain magnetic stimulation, sciatic nerve stimulation produced a more significant EMG enhancement response. This indicated that the magnetic stimulation system could effectively modulate the functions of brain and peripheral nerves by driving the coil. This study provides theoretical and experimental guidance for the subsequent optimization and improvement of practical coils, and lays a preliminary theoretical and experimental foundation for the implementation of magnetic stimulation motion control of animal robots.


Subject(s)
Animals , Columbidae , Robotics , Motion , Brain , Magnetic Phenomena
13.
Chinese Journal of Surgery ; (12): 61-65, 2023.
Article in Chinese | WPRIM | ID: wpr-970174

ABSTRACT

Objective: To examine the application value of 3D Slicer software assisted domestic frameless stereotactic robot in biopsy of intracranial lesions. Methods: A retrospective analysis was performed on 80 patients who admitted consecutively and underwent intracerebral lesions biopsy with the domestic frameless stereotactic robot at Department of Neurosurgery, Aerospace Central Hospital from January 2019 to December 2021. There were 36 males and 44 females, with a mean age of (38.5±18.0) years (range: 6 to 71 years). Before surgery only enhanced T1-weighted three-dimensional magnetization prepared gradient echo sequences and diffusion tensor imaging scans were performed. Self-reconstruction of intracranial lesions, cerebral cortex and blood vessels was carried out using 3D Slicer software system after the DICOM format imaging data of 80 patients were collected. These imaging data were merged to the workstation of the domestic frameless stereotactic robot for preoperative surgical planning and the surgical puncture path was designed to avoid blood vessels in the brain functional area, cerebral cortex and sulcus. Results: All frameless stereotactic biopsy were successfully performed. Postoperative pathological diagnosis included 50 cases of diffuse astrocytic and oligodendroglioma, 15 cases of lymphoma, 5 cases of metastatic tumors, 5 cases of inflammatory demyelinating disease, 2 cases of inflammatory granuloma, 1 case of hemangioma, 1 case of acute lymphoblastic leukemia intracranial invasion and 1 case of seminoma. The positive diagnosis rate was 100% (80/80). Postoperative imaging confirmed that the puncture path and target were accurately implemented according to the preoperative planning, and the target error was (1.32±0.44) mm (range: 0.55 to 1.99 mm). One case of puncture-related bleeding occurred at the target after surgery and improved after treatment. Conclusion: The three-dimensional multimodal images reconstructed by the 3D Slicer software before operation could help the surgeons make the preoperative planning and reduce the risk of stereotactic brain biopsy.


Subject(s)
Male , Female , Humans , Child , Adolescent , Young Adult , Adult , Middle Aged , Aged , Brain Neoplasms/pathology , Diffusion Tensor Imaging , Retrospective Studies , Robotics , Biopsy , Software , Stereotaxic Techniques
14.
Journal of Clinical Otorhinolaryngology Head and Neck Surgery ; (12): 288-292, 2023.
Article in Chinese | WPRIM | ID: wpr-982734

ABSTRACT

Objective:To explore the safety and feasibility of bilateral axillo-breast approach (BABA) robot in the operation of thyroid cancer in obese women. Methods:The clinical data of 81 obese female patients who underwent da Vinci robotic thyroid cancer surgery(robotic group) at the Department of Thyroid and Breast Surgery, PLA 960 Hospital from May 2018 to December 2021 were retrospectively analyzed and compared with the clinical data of 106 obese female thyroid cancer patients who underwent open surgery(open group) during the same period. The age, body mass index(BMI), mean time of surgery, mean postoperative drainage, tumor diameter, postoperative tumor stage, number of lymph node dissection in the central and lateral cervical regions, number of positive lymph nodes in the central and lateral cervical regions, postoperative cosmetic outcome satisfaction score, mean postoperative hospital stay and postoperative complications of all patients were counted. The results were analyzed using SPSS 26.0 statistical software, and the count data were compared using the χ² test, and the measurement data were compared using the t test. Results:All patients completed the operation successfully, and there was no conversion in the robot group, postoperative pathological results were all composed of papillary thyroid carcinoma. The operation time in the robot group was(144.62±36.38) min, which was longer than that in the open group(117.06±18.72) min(P<0.05). The average age of the robot group was(40.25±9.27) years, which was lower than that of the open group(49.59±8.70) years(P<0.05). The satisfactory score of cosmetic effect in the robot group(9.44±0.65) was higher than that in the open group(5.23±1.07)(P<0.05). There was no significant difference in tumor diameter, BMI, average postoperative drainage, temporary hypoparathyroidism and recurrent laryngeal nerve injury, number of central and lateral cervical lymph node dissection, number of positive lymph nodes in the central and lateral cervical regions, and average postoperative hospital stay between the two groups. There was no permanent hypoparathyroidism and recurrent laryngeal nerve injury in both groups. Conclusion:The application of BABA pathway robot in thyroid cancer surgery in obese women is safe and feasible, and the cosmetic effect is better after operation.


Subject(s)
Humans , Female , Adult , Middle Aged , Robotics/methods , Retrospective Studies , Recurrent Laryngeal Nerve Injuries , Thyroidectomy/methods , Carcinoma, Papillary/surgery , Thyroid Neoplasms/pathology , Neck Dissection , Treatment Outcome
15.
Journal of Central South University(Medical Sciences) ; (12): 782-788, 2023.
Article in English | WPRIM | ID: wpr-982348

ABSTRACT

Leiomyosarcoma of urinary bladder (LMS-UB) is a highly malignant mesenchymal tumor, accounting for less than 0.5% of all bladder malignancies, with a predominant clinical presentation of hematuria. Here we report a case of low-grade LMS-UB. A 44-year-old male patient was admitted to the hospital with urodynia for 2 weeks. The patient's pelvis CT showed a mass on the right part of the bladder. For this reason, he was initially diagnosed with bladder cancer. We performed a robot-assisted laparoscopic enucleation of the bladder tumor and low-grade LMS-UB was diagnosed with the histopathological examination. He underwent 5 cycles of adjuvant chemotherapy after surgery. At 19months postoperative follow-up, the patient had no symptoms, recurrence, or distant metastasis. There is no report on the treatment of LMS-UB with minimally invasive enucleation worldwide. This case provides a new comprehensive treatment method of enucleation combined with adjuvant chemotherapy for early low-grade LMS-UB to reduce complications and improve patients' quality of life after surgery.


Subject(s)
Male , Humans , Adult , Urinary Bladder/surgery , Leiomyosarcoma/secondary , Robotics , Quality of Life , Pelvis/pathology , Urinary Bladder Neoplasms/pathology , Laparoscopy/methods
16.
Journal of Central South University(Medical Sciences) ; (12): 716-724, 2023.
Article in English | WPRIM | ID: wpr-982341

ABSTRACT

OBJECTIVES@#Da Vinci robot technology is widely used in clinic,with minimally invasive surgery development. This study aims to explore the possible influence of advanced surgical robotics on the surgery learning curve by comparing the initial clinical learning curves of 2 different surgical techniques: robotic-assisted gastrectomy (RAG) and laparoscopic-assisted gastrectomy (LAG).@*METHODS@#From September 2017 to December 2020, a chief surgeon completed a total of 108 cases of radical gastric cancer from the initial stage, including 27 cases of RAG of the Da Vinci Si robotic system (RAG group) and 81 cases of LAG (LAG group). The lymph node of gastric cancer implemented by the Japanese treatment guidelines of gastric cancer. The surgical results, postoperative complications, oncology results and learning curve were analyzed.@*RESULTS@#There was no significant difference in general data, tumor size, pathological grade and clinical stage between the 2 groups (P>0.05). The incidence of serious complications in the RAG group was lower than the LAG group (P=0.003). The intraoperative blood loss in the RAG group was lower than that in the LAG group (P=0.046). The number of lymph nodes cleaned in the RAG group was more (P=0.003), among which there was obvious advantage in lymph node cleaning in the No.9 group (P=0.038) and 11p group (P=0.015). The operation time of the RAG group was significantly longer than the LAG group (P=0.015). The analysis of learning curve found that the cumulative sum analysis (CUSUM) value of the RAG group decreased from the 10th case, while the CUSUM of the LAG group decreased from the 28th case. The learning curve of the RAG group had fewer closing cases than that of the LAG group. The unique design of the surgical robot might help to improve the surgical efficiency and shorten the surgical learning curve.@*CONCLUSIONS@#Advanced robotics helps experienced surgeons quickly learn to master RAG skills. With the help of robotics, RAG are superior to LAG in No.9 and 11p lymph node dissection and surgical trauma reduction. RAG can clear more lymph nodes than LAG, and has better perioperative effect.


Subject(s)
Humans , Robotics , Robotic Surgical Procedures/methods , Learning Curve , Stomach Neoplasms/pathology , Retrospective Studies , Laparoscopy/methods , Lymph Node Excision/methods , Gastrectomy/methods , Treatment Outcome
17.
China Journal of Orthopaedics and Traumatology ; (12): 465-472, 2023.
Article in Chinese | WPRIM | ID: wpr-981716

ABSTRACT

OBJECTIVE@#To evaluate the early clinical efficacy of robot-assisted percutaneous short-segment bone cement-augmented pedicle screw fixation in the treatment of stageⅡ-Ⅲ Kümmell disease.@*METHODS@#The clinical data of 20 patients with stageⅡ-Ⅲ Kümmell's disease who underwent robot-assisted percutaneous bone cement-augmented pedicle screw fixation between June 2017 and January 2021 were retrospectively analyzed. There were 4 males and 16 females, aged from 60 to 81 years old with an average age of (69.1±8.3) years. There were 9 cases of stageⅡand 11 cases of stage Ⅲ, all of which were single vertebral lesions, including 3 cases of T11, 5 cases of T12, 8 cases of L1, 3 cases of L2, and 1 case of L3. These patients did not exhibit symptoms of spinal cord injury. The operation time, intraoperative blood loss, and complications were recorded. The position of pedicle screws and the filling and leakage of bone cement in gaps were observed using postoperative CT 2D reconstruction. The data of the visual analogue scale (VAS), Oswestry disability index (ODI), kyphosis Cobb angle, wedge angle of the diseased vertebra, and anterior and posterior vertebral height on lateral radiographs were statistically analyzed preoperatively, 1 week postoperatively, and at the final follow-up.@*RESULTS@#Twenty patients were followed up for 10 to 26 months, with an average follow-up of (16.0±5.1) months. All operations were successfully completed. The surgical duration ranged from 98 to 160 minutes, with an average of (122±24) minutes. The intraoperative blood loss ranged from 25 to 95 ml, with an average of (45±20) ml. There were no intraoperative vascular nerve injuries. A total of 120 screws were inserted in this group, including 111 screws at grade A and 9 screws at grade B according to the Gertzbein and Robbins scales. Postoperative CT indicated that the bone cement was well-filled in the diseased vertebra, and cement leakage occurred in 4 cases. Preoperative VAS and ODI were (6.05±0.18) points and (71.10±5.37)%, respectively, (2.05±0.14) points and (18.57±2.77)% at 1 week after operation, and (1.35±0.11) points and (15.71±2.12) % at final follow-up. There were significant differences between postoperative 1 week and preoperative, and between final follow-up and postoperative 1 week(P<0.01). Anterior and posterior vertebral height, kyphosis Cobb angle, and wedge angle of the diseased vertebra were(45.07±1.06)%, (82.02±2.11)%, (19.49±0.77) °, and (17.56±0.94) ° preoperatively, respectively, (77.00±0.99)%, (83.04±2.02)%, (7.34±0.56) °, and (6.15±0.52) ° at 1 week postoperatively, and (75.13±0.86)%, (82.39±0.45)%, (8.38±0.63) °, and (7.09±0.59) ° at the final follow-up.@*CONCLUSION@#Robot-assisted percutaneous short-segment bone cement-augmented pedicle screw fixation demonstrates satisfactory short-term efficacy in treating stageⅡ-Ⅲ Kümmell's disease as an effective minimally invasive alternative. However, longer operation times and strict patient selection criteria are necessary, and long-term follow-up is required to determine its lasting effectiveness.


Subject(s)
Male , Female , Humans , Middle Aged , Aged , Aged, 80 and over , Pedicle Screws , Bone Cements , Robotics , Blood Loss, Surgical , Retrospective Studies , Spinal Fractures/surgery , Lumbar Vertebrae/injuries , Treatment Outcome , Kyphosis , Thoracic Vertebrae/injuries , Fracture Fixation, Internal
18.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 404-409, 2023.
Article in Chinese | WPRIM | ID: wpr-981606

ABSTRACT

OBJECTIVE@#To compare the short-term effectiveness of "SkyWalker" robot-assisted total knee arthroplasty (TKA) and traditional TKA.@*METHODS@#A clinical data of 54 patients (54 knees) with TKA who met the selection criteria between January 2022 and March 2022 was retrospectively analyzed. Among them, 27 cases underwent traditional TKA (traditional operation group) and 27 cases underwent "SkyWalker" robot-assisted TKA (robot-assisted operation group). There was no significant difference between the two groups ( P>0.05) in terms of gender, age, body mass index, osteoarthritis side, disease duration, and preoperative Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), visual analogue scale (VAS) score, hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and posterior proximal tibial angle (PPTA). The operative time, intraoperative bleeding volume, surgery-related complications, the KSS, WOMAC, and VAS scores before operation and at 6 months after operation, and Forgotten Joint Score (FJS) at 6 months after operation were recorded. X-ray films were taken to review the prosthesis position and measure HKA, LDFA, MPTA, and PPTA. The differences of the clinical and imaging indicators between before and after operation were calculated and statistically analyzed.@*RESULTS@#The operations were completed successfully in both groups. There was no significant difference in the operative time and intraoperative bleeding volume between the two groups ( P>0.05). After operation, 1 case of incision nonunion and 1 case of heart failure occurred in the traditional operation group, while no surgery-related complications occurred in the robotic-assisted operation group. The incidences of surgical complications were 7.4% (2/27) in the traditional operation group and 0 (0/27) in the robotic-assisted operation group, with no significant difference ( P=0.491). Patients in both groups were followed up 6 months. KSS score, WOMAC score, VAS score, and ROM significantly improved in both groups at 6 months after operation when compared with preoperative ones ( P<0.05). There was no significant difference between the two groups ( P>0.05) in the differences between the pre- and post-operative values of the clinical indicators and FJS scores at 6 months after operation. X-ray films showed that the lower extremity force lines of the patients improved and the knee prostheses were in good position. Except for LDFA in the robot-assisted operation group, HKA, LDFA, MPTA, and PPTA significantly improved in both groups at 6 months after operation when compared with the preoperative ones ( P<0.05). There was no significant difference between the two groups in the differences between the pre- and post-operative values of the radiological indicators ( P>0.05).@*CONCLUSION@#The "SkyWalker" robot-assisted TKA is one of the effective methods for the treatment of knee osteoarthritis and had good short-term effectiveness. But the long-term effectiveness needs to be further studied.


Subject(s)
Humans , Arthroplasty, Replacement, Knee/methods , Knee Joint/surgery , Knee Prosthesis , Osteoarthritis, Knee/surgery , Retrospective Studies , Robotics , Treatment Outcome
19.
Journal of Biomedical Engineering ; (6): 327-334, 2023.
Article in Chinese | WPRIM | ID: wpr-981546

ABSTRACT

The neural stimulator is a core component of animal robots. While the control effect of animal robots is influenced by various factors, the performance of the neural stimulator plays a decisive role in regulating animal robots. In order to optimize animal robots, embedded neural stimulators had been developed using flexible printed circuit board technology. This innovation not only enabled the stimulator to generate parameter-adjustable biphasic current pulses through control signals, but also optimized its carrying mode, material, and size, overcoming the disadvantages of traditional backpack or head-inserted stimulators, which have poor concealment and are prone to infection. Static, in vitro, and in vivo performance tests of the stimulator demonstrated that it not only had precise pulse waveform output capability, but also was lightweight and small in size. It had excellent in vivo performance in both laboratory and outdoor environments. Our study has high practical significance for the application of animal robots.


Subject(s)
Animals , Robotics
20.
Cambios rev med ; 21(2): 875, 30 Diciembre 2022. grafs.
Article in Spanish | LILACS | ID: biblio-1413853

ABSTRACT

INTRODUCCIÓN. La cirugía robótica se realiza gracias al sistema telemanipulado, alcanzando tareas repetitivas, precisas y mínimamente invasivas. En Ecuador inició en el año 2016, incluyendo este procedimiento a pediatría en el 2021. OBJETIVO. Describir las características clínicas y resultados quirúrgicos de pacientes pediátricos intervenidos por cirugía robótica. MATERIALES Y MÉTODOS. Estudio transversal analítico. Población de 278 y muestra de 40 datos de historias clínicas electrónicas de pacientes pediátricos intervenidos por cirugía robótica de agosto del 2021 a marzo del 2022 en el Hospital Carlos Andrade Marín. Criterios de inclusión: pacientes pediátricos intervenidos por cirugía robótica en el Hospital de Especialidades Carlos Andrade Marín. Criterios de exclusión: pacientes adultos, haber sido intervenidos quirúrgicamente por técnicas abiertas o laparoscópica. La información se obtuvo del sistema AS400; se creó una base de datos anonimizando a los pacientes. Se aplicó un análisis univariado y para determinar significancia estadística se utilizó la prueba de Chi-2. La información recolectada fue analizada en el programa estadístico International Business Machines Statistical Package for the Social Sciences. RESULTADOS: De los pacientes del estudio: 45,00% (18; 40) era adolescente. El 52,50% (21; 40) no presentó comorbilidades. 50,00% (20; 40) de las intervenciones fueron colecistectomía. 55% (22; 40) fué por diagnóstico prequirúrgico y posquirúrgico gastrointestinal y hepático. El 95,00% (38; 40) no presentó complicaciones. El 100% (40; 40) presentó sangrado G1. El 97,50% (39; 40) no presentó eventos, y el 72,5% (29; 40) no presentó dolor. El promedio de peso de los pacientes fue 41 kilogramos, con una media de 3 días de estancia hospitalaria, un promedio de 65 minutos de cirugía total y 15 minutos de docking, los cuales son estadísticamente significativos con una p= 0,001. CONCLUSIONES. Se registró las características clínicas y resultados quirúrgicos de pacientes pediátricos intervenidos por cirugía robótica. La cirugía robótica se aplicó con seguridad en pacientes pediátricos del Hospital Carlos Andrade Marín.


INTRODUCTION. Robotic surgery is performed thanks to the telemanipulated system, achieving repetitive, precise and minimally invasive tasks. In Ecuador it started in the Hospital de Especialidades Carlos Andrade Marín in 2016, including this procedure to pediatrics in 2021. OBJECTIVE. To describe the clinical characteristics and surgical outcomes of pediatric patients operated by robotic surgery. MATERIALS and METHODS. Analytical cross-sectional study. Population of 278 and sample of 40 data from electronic medical records of pediatric patients operated by robotic surgery from August 2021 to March 2022 at the Carlos Andrade Marin Hospital. Inclusion criteria: pediatric patients who underwent robotic surgery at the Hospital de Especialidades Carlos Andrade Marín. Exclusion criteria: adult patients, having undergone open or laparoscopic surgery. The information was obtained from the AS400 system; a database was created by anonymizing the patients. Univariate analysis was applied and the Chi-2 test was used to determine statistical significance. The information collected was analyzed in the statistical program International Business Machines Statistical Package for the Social Sciences. RESULTS: Of the patients in the study: 45,00% (18; 40) were adolescents. 52,50% (21; 40) had no comorbidities. 50,00% (20; 40) of the interventions were cholecystectomy. 55% (22; 40) were for preoperative and postoperative gastrointestinal and hepatic diagnosis. 95,00% (38; 40) had no complications. 100% (40; 40) presented G1 bleeding. 97.50% (39; 40) did not present events, and 72,5% (29; 40) did not present pain. The average weight of the patients was 41 kilograms, with a mean hospital stay of 3 days, an average of 65 minutes of total surgery and 15 minutes of docking, which are statistically significant with a p= 0,001. CONCLUSIONS. The clinical characteristics and surgical results of pediatric patients who underwent robotic surgery were recorded. Robotic surgery was safely applied in pediatric patients at the Carlos Andrade Marin Hospital.


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , Pediatrics , Surgery Department, Hospital , Surgical Instruments , Robotics , Plastic Surgery Procedures , Robotic Surgical Procedures , Respiratory Tract Infections , Cardiovascular Diseases , Child Health Services , Laparoscopy , Ecuador , Endocrine System Diseases , Gastrointestinal Diseases , Varicocele , Hemorrhage , Neurologic Manifestations
SELECTION OF CITATIONS
SEARCH DETAIL